Featured Solutions
Highlighted solutions for the trauma specialty.
Skeletal Dynamics
Internal joint stabilizer for the unstable elbow.
- Permits early, active motion and protects repaired soft tissues without ex-fix related complications.
- Preassembled, low-profile construct for internal application.
- Centering guides pinpoint the axis of rotation.
Request a meeting or in-service
Skeletal Dynamics
ALIGN® radial head, Proximal Ulna Plate and IJS® Elbow from one Distal Elbow Set.
- Five systems in two trays: proximal ulna and PROTEAN® plating, REDUCT® screws, ALIGN® radial head and IJS® Elbow.
- Designed to manage distal elbow fracture-dislocations with one comprehensive system.
Request a meeting or in-service
Skeletal Dynamics
Distal and midshaft humerus fracture plating.
- TiBeam® connects the medial and lateral plates into a single fixed-angle construct, with compression across the trochlea.
- FREEFIX® slots take compression or locking screws anywhere in the slot.
- Midshaft and supracondylar plates in 146–262 mm lengths.
Request a meeting or in-service
Skeletal Dynamics
FREEFIX® midshaft and supracondylar humerus plates.
- Supracondylar plate with a distal extension in 142, 196 and 250 mm; midshaft narrow and broad plates from 136 to 244 mm.
- Designed for torsional resistance, with staggered screw holes for multiplanar fixation.
- Compression or locking screws can go in any position in the FREEFIX® slots.
Request a meeting or in-service
Skeletal Dynamics
Proximal humerus fracture plate.
- 6.0 mm central locking peg at 135°.
- Curved, deltoid-sparing plate that sits low to reduce impingement.
- Blunt-tipped pegs and screws to reduce the risk of joint-surface penetration.
Request a meeting or in-service
Skeletal Dynamics
Olecranon and proximal ulna plate.
- Designed to fix the proximal tip of the olecranon and prevent avulsion of the triceps insertion.
- Single home-run tab and an optimized home-run screw trajectory.
- Deepened central concavity for the PUDA and dorsal ulnar ridge; suture holes for soft-tissue repair.
Request a meeting or in-service
Skeletal Dynamics
Radial head arthroplasty aligned to the axis of forearm rotation.
- Monoblock implant adjusts 11° in any direction, then locks to match the patient’s anatomy.
- Atraumatic dish to minimize capitellar wear.
- Extra-long stem with distal flutes for three-point fixation and to prevent stem rotation.
Request a meeting or in-service
Skeletal Dynamics
Dorsal bridge plate for the wrist.
- Anatomically designed to ease insertion and improve reduction.
- 10° of volar apex angulation places the hand in a position of improved function.
- Handle gives grip, leverage and direction for controlled insertion.
Request a meeting or in-service
Bone Support
Injectable bone void filler with gentamicin.
- 40% hydroxyapatite and 60% calcium sulfate, with gentamicin.
- Designed to resorb at the rate bone forms; the hydroxyapatite is osteoconductive.
- Gentamicin protects the void against colonization by gentamicin-sensitive organisms.
Request a meeting or in-service
ETS
Borate-based bioactive glass fiber matrix for complex wounds.
- Soft, fibrous matrix that conforms to irregular wound beds and stays in place in deeper, tunneled, and undermined wounds.
- Porous scaffold that supports granulation tissue and re-epithelialization as the wound closes.
- Facilitates a wound-healing environment conducive to angiogenesis, the new blood vessel formation that granulation tissue depends on.
Request a meeting or in-service
Biocomposites
Calcium sulfate bone void filler.
- Absorbable, fully synthetic calcium sulfate.
- No hydroxyapatite, insoluble impurities or PMMA debris; absorbs completely.
- Can be placed at infected or non-infected sites; it does not treat infection itself.
Request a meeting or in-service
Skeletal Dynamics
Radius and ulna shaft plating (FREEFIX®).
- FREEFIX® slots let the fracture dictate screw placement.
- Callomimetic design: plate strength tapers along its length to unload stress to the bone.
- Indication-specific radius and ulna plates, 81–188 mm.
Request a meeting or in-service
FX Shoulder
Reverse shoulder interlocking long stem (180/200 mm).
- Interlocking screws (18–36 mm) on the distal stem for complex fractures.
- Plasma-sprayed titanium and HA coating proximally, designed for cementless fixation.
- Suture holes and a medial recess proximally for sutures if needed.
Request a meeting or in-service